Tewameter® Triple TM 330T
back
New - Three heads in one probe of the worldwide most used device for transepidermal waterloss
With this innovative new probe of the Tewameter® a variety of additional options are available for the users.
The Measuring Principle
The open chamber measurement of the Tewameter® is the only method to assess the TEWL continuously, which is necessary for most applications without influencing the skin surface. Numerous studies are available.
Advantages of the Tewameter® Triple TM 330T
Why using 3 Tewameter® heads at the same time?
Apart from the many advantages of the Tewameter® in general, the Tewameter® Triple TM 330T offers additional benefits
The Probe Heater PR 100
The sensors of the probe normally have room temperature (20-22°C), whereas skin temperature is 30°C and higher. As the amount of evaporating water measured with the device is extremely small (healthy skin 8-15 g/h/m² → 0.000001333 - 0.00000025 g/minute/cm²), the sensors inside the probe should reach skin temperature to measure this small amount exactly and stable. With the probe heater the probe head is constantly warmed up to a temperature close to skin temperature and thus getting very quickly accurate and stable results. The probe heater can of course also be used for other C+K probes.
Fields of Application
The measurement of the Tewameter® is the basic measurement for all cosmetic applications. The three head probe is also especially suitable for sweat studies and an ideal tool for multicentric investigations.
Special Accessories Tewameter® Triple TM 330T Probe Heads
There are specials adapters available for the heads.
Closed Chamber Measurements with the Tewameter®
The Tewameter® is the worldwide only device which measures with open chamber as well with closed chamber by a special semipermeable adapter cap. The closed chamber is useful for measurements under suboptimal environmental conditions like in field tests or in some occupational surroundings to minimize air turbulences inside the probe.
The Tewameter® Triple TM 330T can be connected to the MPA-systems.
Do not switch in one study between the standard Tewameter® TM 300 and the Tewameter® Triple TM 330T
Technical Data
For the probe only:
Dimensions: 3 measuring chambers: each 2 cm, Ø 1 cm, length of the probe: approx. 24 cm, width, when all chambers are located close together: approx. 6.4 cm, cable length: 1.3 m,
Weight: approx. 120 g,
Resolution: relative humidity ± 0.01 % RH, Temp.: ± 0.01 °C, TEWL: 0.1 g/h/m²,
Measuring area: TEWL 0-320 g/h/m²
Accuracy:
Rel. Humidity (RH): ± 1.8 %, Temperature: ± 0.2 °C
TEWL:
between 10 % and 80 % RH: ± 0.25 g/h/m² for TEWL values up to 5 g/h/m² and 5 % for values over
5 g/h/m²
0 -10 % and > 80 % RH: ± 1 g/h/m² for TEWL values up to 5 g/h/m² and 10 % for values under 5 g/h/m²
Technical changes may be made without prior notice.